whatsapp
  • Call us

    +91 95865 68656

  • Send us mail

    info@voltsonindia.com

Cable Structure
Copper Fine Stranded Copper (Class 5 - Flexible Plain Copper) to VDE 0295 IEC 60228
Insulation/sheath HO5VVF : PVC
HO5V2V2F: Heat Resistant PVC
Colour White, Black, Blue or as per party order
Flame propagation Zero halogen IEC 60754-2, Flame retardant test as per IEC 60332-1
Technical Data
Operating Temperature H05VV-F : -20°c to +80°C
H05V2V2-F : -20°c to +90°C
Nominal Voltage H05VV-F : 300/500 V
H05V2V2-F : 300/500 V
Test Voltage H05VV-F : 2.5KV
H05V2V2-F : 2.5KV
Insulation resistance Min. 20 MΩ x km
Min. bending radius 7 x cable diameter
Application
H05VV-F, H05V2V2-FHH05VV-F AND H05V2V2-F cordage is flexible PVC insulated, PVC jacketed harmonized cord recommended for use in electronic and electrical equipment such as office
Standard length cable packing: Coils 100 and 200 , in carbon boxes, reels
Features
Good application of insulation Excellent mechanical & electrical properties
Special heat resistant insulation Harmonized acc. To European standards
High current carrying capacity Steam and boiling water resistant
Excellent resistant to moisture, abrasion, grace and oil. Tested by SGS, EIL, RITES, NCP, INTERTEK
Color Coding: AS IS 1554 ( Indian Standard )
Single Core 2 Core 3 Core 4 Core 5 Core
Red, Black Red, Black Red, Yellow and Blue Red, Yellow, Blue, Black Red, Yellow, Blue, Black, Grey
Color Coding: AS IS 1554 ( Indian Standard )
Single Core 2 Core 3 Core 4 Core 5 Core
Black or Yellow/Green Blue and Brown or Yellow-Green and Black Brown, Black, Grey or Yellow/Green, Blue, Brown Blue, Brown, Black, Grey or Yellow/Green, Brown, Black, Grey Blue, Brown, Black, Grey, Black or Yellow/Green, Blue, Brown, Black, Grey
H05VV-F (300/500 V)
Nominal cross sectional area of conductor Nominal insulation thickness Nominal sheath thickness in mm Max overall diameter in mm Max conductor resistance at 20°C Min insulation resistance at 70°C
2 core 3 core 4 core 5 core 2 core 3 core 4 core 5 core
Lower limit Upper limit Lower limit Upper limit Lower limit Upper limit Lower limit Upper limit
sqmm mm sqmm sqmm sqmm sqmm sqmm sqmm sqmm sqmm sqmm sqmm sqmm sqmm Ω/km MΩkm
0.75 0.6 0.8 0.8 0.8 0.9 5.7 7.2 6 7.6 6.6 8.3 7.4 9.3 26 0.011
1.0 0.6 0.8 0.8 0.9 0.9 5.9 7.5 3.3 8 7.1 9 7.8 9.8 19.5 0.01
1.5 0.7 0.8 0.9 1.0 1.1 6.8 8.6 7.4 9.4 8.4 10.5 9.3 11.6 13.3 0.01
2.5 0.8 1.0 1.0 1.1 1.2 8.4 10.6 9.2 11.4 10.1 12.5 11.2 13.9 7.98 0.0095
4.0 0.8 1.1 1.2 1.2 1.4 9.7 12.1 10.5 13.1 11.5 14.3 13 16.1 4.95 0.0078
H05V2V2-F (300/500 V)
Nominal cross sectional area of conductor Nominal insulation thickness Nominal sheath thickness in mm Max overall diameter in mm Max conductor resistance at 20°C Min insulation resistance at 70°C
2 core 3 core 4 core 5 core 2 core 3 core 4 core 5 core
Lower limit Upper limit Lower limit Upper limit Lower limit Upper limit Lower limit Upper limit
sqmm mm sqmm sqmm sqmm sqmm sqmm sqmm sqmm sqmm sqmm sqmm sqmm sqmm Ω/km MΩkm
0.75 0.6 0.8 0.8 0.8 0.9 5.7 7.2 6 7.6 6.6 8.3 7.4 9.3 26 0.011
1.0 0.6 0.8 0.8 0.9 0.9 5.9 7.5 3.3 8 7.1 9 7.8 9.8 19.5 0.01
1.5 0.7 0.8 0.9 1.0 1.1 6.8 8.6 7.4 9.4 8.4 10.5 9.3 11.6 13.3 0.01
2.5 0.8 1.0 1.0 1.1 1.2 8.4 10.6 9.2 11.4 10.1 12.5 11.2 13.9 7.98 0.0095
4.0 0.8 1.1 1.2 1.2 1.4 9.7 12.1 10.5 13.1 11.5 14.3 13 16.1 4.95 0.0078
  • All are class 5 flexible conductor
  • Insulation grade is EI5
  • Sheathing grade is TM3