Cable Structure
Generally conforms to, BS EN 50525 CENELEC HD 22-6 , DIN VDE 0282 ,IEC 245-6
Copper Extra-fine class 5 conductor for H01N2-D & class 6 for H01N2-E conforms to IEC 60228, DIN VDE 0295
Separation Polyester tape
Outer Sheat HOFR Sheath (Polychloroprene), black and oil resistant
* Any color can be supplied as per the requirement and wish of the buyer.
Technical Data
Fixed installation 30°c to max.+90°C
Nominal Voltage 600 V
Test Voltage 1000V
Min. bending radius 4 x cable diameter
Flame propagation Flame retardant test as per IEC 60332-1
Application
Designed for the secondary (high current) connection to automatic or hand – held metal arc welding electrodes
Suitable for flexible use under rugged conditions, on assembly lines and conveyor systems, in machine tool and automatically operated line and spot welding machines
Standard length cable packing: Coils 100, 200,300 and 500m. in wooden reels
Features
Ultra high performance flexible welding lead, double insulated
Better flame retardant properties
Excellent flexibility to last longer in flex applications Based on CENELEC HD 22-6 31, VDE 0282, IEC 245-6, IS 473, BS 638-4
Outstanding toughness & durability
High resistance to cuts, tears & abrasion
Resistance to oil, solvents and chemicals
Excellent ozone and weather resistant.
Cable Design
A Submersible Pump Cable is a specialized product to be used for submersible pump in a deep well. The area of installation is physically restrictive, and the environment is very hostile. Voltson is designed and manufacured keeping in mind these factors to achieve the highest possible degree of reliability.
H01N2-D welding cable
Nominal cross sectional area of conductor Nominal sheath thickness Mean overall dimeter Max conductor resistance at 20°C
Lower lmit Outer limit
Sq. mm. mm mm mm Ω/km
10 2.0 7.7 9.7 1.91
16 2.0 8.8 11.0 1.21
25 2.0 10.1 12.7 0.780
35 2.0 11.4 14.2 0.554
50 2.2 13.2 16.5 0.386
70 2.4 15.3 19.2 0.272
95 2.6 17.1 21.4 0.206
120 2.8 19.2 24 0.161
150 3.0 21.1 26.4 0.129
185 3.2 23.1 28.9 0.106
H01N2-D welding cable
Nominal cross sectional area of conductor Nominal sheath thickness Mean overall dimeter Max conductor resistance at 20°C
Lower lmit Outer limit
Sq. mm. mm mm mm Ω/km
10 1.20 6.2 7.8 1.91
16 1.20 7.3 9.1 1.21
25 1.20 8.6 10.8 0.780
35 2.0 11.4 14.2 0.554
35 1.20 9.8 12.3 0.554
50 1.50 11.9 14.8 0.386
70 1.50 13.6 17 0.272
95 1.80 15.6 19.5 0.206
120 1.80 17.2 21.6 0.161
150 1.80 18.8 23.5 0.129
185 1.80 20.4 25.5 0.106
  • All are flexible conductor
  • Insulation material is NBR
  • Sheath material is NBR