Cable Structure
Generally conforms to, BS EN 50525 CENELEC HD 22-6 31, VDE 0282 ,IEC 245-6, BS 6899 , IS 6830/84
Copper High conductivity, bare annealed copper flexible conductor, EC copper class 5 and class 6 generally conforms to IEC 60228, DIN VDE 0281
Insulation Double Insulated flexible Nitrile rubber (NBR) insulated
Color Core Orange & Black Jacket
* Any color can be supplied as per the requirement and wish of the buyer.
Technical Data
Fixed installation 30°c to max.+90°C
Nominal Voltage 600 V
Test Voltage 3000V
Insulation resistance Min. 10 MΩ x km
Min. bending radius 6 x cable diameter
Flame propagation Flame retardant test as per IEC 60332-1
Application
Designed for the secondary (high current) connection to automatic or hand – held metal arc welding electrodes
Suitable for flexible use under rugged conditions, on assembly lines and conveyor systems, in machine tool and automatically operated line and spot welding machines
Standard length cable packing: Coils 100, 200,300 and 500m. in wooden reels
Features
Ultra high performance flexible welding lead, double insulated
Better flame retardant properties
Excellent flexibility to last longer in flex applications Based on CENELEC HD 22-6 31, VDE 0282, IEC 245-6, IS 473, BS 638-4
Outstanding toughness & durability
High resistance to cuts, tears & abrasion
Resistance to oil, solvents and chemicals
Excellent ozone and weather resistant.
Cable Design
A Submersible Pump Cable is a specialized product to be used for submersible pump in a deep well. The area of installation is physically restrictive, and the environment is very hostile. Voltson is designed and manufacured keeping in mind these factors to achieve the highest possible degree of reliability.
Technical Data Table
Current Rating : The maximum current ratings of flexible welding cables for different duly cycles are based on an ambient air temperature of 25°C and a maximum conductor temperature of 90°C. The percentage duly cycles for various processes and applications are as follows:
Automobile Welding : Up to 100%
Manual Welding : 0% to 60%
Very intermittent or Occasional Welding : Up to 20%
Voltage Drop : When total cable lengths in excess of 15 mtrs., are involved , it may be necessary to use cables of larger cross section to ensure that the voltage drop is not excessive and welding currents are maintained at adequate levels.
NBR/NBR welding cable
Nominal cross sectional area of conductor Nominal insln thickness Nominal insln thickness Overall cable diameter Max conductor resistance at 20°C Current rating
Welding applications Non Welding Application
Duty Cycle
Lower limit Upper limit 100% 85% 60% 30% 20%
Sq. mm. mm mm mm mm Ω/km Amps. Amps. Amps. Amps. Amps. Amps.
10 1.20 1.80 7.80 10.0 1.91 105 115 135 190 235 110
16 1.20 1.90 9.00 11.5 1.21 135 145 175 245 302 138
25 1.40 2.00 10.0 13.0 0.780 180 195 230 330 402 187
35 1.40 2.20 11.5 14.5 0.554 225 245 290 410 503 233
50 1.60 2.40 13.0 17.0 0.386 285 310 370 520 637 295
70 1.60 2.60 15.0 19.0 0.272 355 385 460 650 794 372
95 1.80 2.80 17.5 21.5 0.206 430 470 560 790 961 449
120 1.80 3.00 19.5 24 0.161 500 540 650 910 1118 523
150 2.00 3.20 21.5 26 0.129 580 620 740 1040 1297 608
185 2.20 3.40 23.0 29 0.106 660 715 850 1200 1476 690
240 2.40 3.50 27.0 32 0.0801 710 770 916 1296 1587 744
300 2.60 3.60 30.0 35 0.0641 800 850 1035 1450 1790 840
400 2.80 3.80 33.0 39 0.0486 925 1000 1195 1690 2070 970
  • All are flexible conductor
  • Insulation material is NBR
  • Sheath material is NBR
Rating factors for variation in ambient temprature
Ambient temperature °C 20° 25° 30° 35° 40° 45° 50° 55° 60° 65°
Ambient temperature °C 1.04 1.00 0.96 0.91 0.87 0.82 0.76 0.69 0.64 0.57